JavaScript Menu by Deluxe-Menu.com

Plant Relocation (Southwest)

HETSCO served as the contractor for the relocation and construction of a 550 TPD air separation plant from Vineyard, UT to Tupman, CA and provided the following services:

  • Bracing and Supports for PHX Box, N2 Superheater Box & Column Box
  • Relocate Compressor Motors, Cryogenic Storage Tanks, Automatic Valves and Instrumentation, Dust Filter, DCA, Piping.
  • Remove/Erect PHX (48'/148,900 lb.), N2 Superheater (67'/75,000 lb.), Column Package (100'/107,000 lb.)
  • Provided Engineering Calculations and Drawings for Dismantling and scrapping Argon Column
  • Provided Transportation for all Equipment
  • Relocate and Install Turbine Expander with Modifications
  • 2 Dimensional Alignment and structurally modified PHX, Columns, & Ducts to meet Seismic Requirements
  • Extensive Piping Modifications to N2 Column for Process Requirements
  • Removal and Modifications to Column Trays and Downcomers
  • Grouting of PHX and Column
  • Pressure Testing of PHX, Superheater, Column and all Associated Piping
  • Oxygen Cleaning of necessary Piping
  • NDT of Weld Requirements to B31.3

 


Projects

Tupman-vineyard_1096
Tupman-vineyard_851